Med Evolution
Download Our Catalogs
Mother & Child Products
Procedure Trays & Kits
Biopsy Needles
Feature Products

Bone Marrow Biopsy

PenBone

 

Needle for Sternal or Iliac Crest Marrow Aspiration, Light Version

PenBone needle (PI) is a disposable device for sternal or iliac aspiration with high reliability performance. PI needle is equipped with an atraumatic cannula with Chiba type sharpening that has been made of AISI 304 stainless steel tempered in accordance with international standards.

The needle has an adjustable safety stop that allows to easily determine, thank also to the centimeter markings on the cannula surface, the length of the cannula and the depth of insertion.

The stylet, is coupled to the handle by a "bayonet" attack to avoid its moving back during introduction.

The needle has a Luer-lock that allows the attachment of the syringe for a safety and fast aspiration of the bone marrow. The perfect matching between cannula and stylet, off ers a safe penetration in the cortical bone.

The tip shape is designed to facilitate the needle insertion keeping high mechanic strength. On the handle has shown the gauge size of the needle.

The removable depth stop, allows to use the device in its maximum length.
 
Code Gauge Minimum Length Maximum Length
PI1535/100 15G 35 mm 100 mm
PI1525/90 15G 25 mm 90 mm
PI1510/75 15G 10 mm 75 mm
PI1635/100 16G 35 mm 100 mm
PI1625/90 16G 25 mm 90 mm
PI1610/75 16G 10 mm 75 mm
PI1835/100 18G 35 mm 100 mm
PI1825/90 18G 25 mm 90 mm
PI1810/75 18G 10 mm 75 mm
 
 
 
 

ILLY

 

Needle for Medullar Aspiration with Ergonomic Handle

Illy needle (PIL), is a disposable device for high reliability performance of medullar aspiration.

The device is equipped with an atraumatic cannula with Chiba type sharpening made of AISI 304 stainless steel tempered in accordance with international standards.

Illy has an adjustable safety stop that allows to easily determine, thank also to the centimeter markings on the cannula surface, the length of the cannula and the depth of insertion. The stylet is coupled to the handle by a "bayonet" attack to avoid its moving back in course of introduction.

The needle has a Luer-lock the allows the attachment of the syringe for a safety and fast aspiration of the bone marrow. The perfect coupling between cannula and stylet, off ers a safe penetration into the cortical bone.

The tip shape is designed to facilitate the insertion of the needle into the bone, keeping the mechanic strength. The "T" ergonomic handle off ers optimal pressure and secure grip to facilitate the penetration step into the cortical. On the handle has shown the gauge size of the needle.

The removable depth stop, allows to use the device in its maximum length.
 
Code Gauge Minimum Length Maximum Length
PIL1410/75 14G 10 mm 75 mm
PIL1535/100 15G 35 mm 100 mm
PIL1520/85 15G 20 mm 85 mm
PIL1510/75 15G 10 mm 75 mm
PIL1635/100 16G 35 mm 100 mm
PIL1620/85 16G 20 mm 85 mm
PIL1610/75 16G 10 mm 75 mm
PIL1835/100 18G 35 mm 100 mm
PIL1820/85 18G 20 mm 85 mm
PIL1810/75 18G 10 mm 75 mm
 
 
 
 

Harvest

 

Needle for biopsy or transplantation procedure of bone marrow

Harvest (Code : PJE) is a disposable device specifically designed for bone marrow removal and for Haemopoietic stem cells transplantation procedure (HSCT). It is provided with:

Dot Cannula with “diamond” sharpening and with 5 slides holes arranged at 180? to optimise the aspiration capacity of the marrow blood (containing haemopoietic cells) and to reduce the procedure time.
Dot Stylet with pyramidal tip to maximize the introduction capacity through the bone cortical.

The holes on the cannula are arranged in alternate way to make quick and efficient extraction of Haemopoietic stem cells (HTC) from the posterior iliac crest.
 
Code Gauge Length Color Code
PJE1306 13G 60 mm Cyan
PJE1310 13G 100 mm Cyan
PJE1110 11G 100 mm White
PJE1115 11G 150 mm White
PJE0810 8G 100 mm Green
 
 
 
 

OsteoJ

 

Bone Marrow Biopsy Needle

OsteoJ (PJ) is a device for bone tissue biopsy, provided with ergonomic handle to distribute in an optimal way, the pressure applied by the operator during the introduction in the cortical bone. The needle is equipped with a cannula made of AISI 304 stainless tempered steel in accordance with international standards. The centimeter markings on the cannula surface, allow to easily determine the depth of insertion into the bone tissue. The special sharpening at "fi sh mouth" of the needle tip, improves the penetration capacity establishing a perfect cylindrical cutting that maintains intact the sample architecture.

OsteoJ needle is equipped with a security system with rotation coupling which avoids the moving back risk of the stylet during the insertion step.

OsteoJ needle is equipped with a stylet with trocar pyramidal tip to allow a quick and less invasive penetration into the cortical. On the packaging is stamped the needle diameter with international color code.

The extraction wire has a measuring function of the specimen quantity present into the cannula and off ers added safety for biopsy specimen extraction.

The handle is provided with a sharpened Luer-lock to off er a more safety attachment to the syringe. Aspiration can be performed at any step of the procedure.

The set includes
Dot Extraction wire to insert into the cannula tip
Dot Luer-lock cap (on the handle) to avoid the blood loss during the extraction step.
 
Code Gauge Length Color Code
PJ1306 13G 60 mm Cyan
PJ1310 13G 100 mm Cyan
PJ1110 11G 100 mm White
PJ1115 11G 150 mm White
PJ0810 8G 100 mm Green
 
 
 
 

PickUp

 

Bone marrow biopsy needle without luxation

PickUp (PJT) is a device for bone tissue biopsy provided with an external trap system that allows the tissue extraction without luxation. The ergonomic handle is designed to distribute in an optimal way, the pressure applied by the operator during the introduction into the cortical bone. The cannula of the needle, made with high quality stainless tempered steel, shows on its surface, centimeter markings that allow to easily determine the insertion depth into the bone tissue. The special "fi sh mouth" sharpening of the needle tip, improves the penetration capacity, establishing a perfect cylindrical cutting that maintains intact the architecture of the sample.

PickUp needle is equipped with a security system with rotation coupling which avoids the moving back risk of the stylet during the insertion. The handle is provided with a sharpened Luer-lock to off er an added safety attachment to the syringe. Aspiration can be performed at any step of the procedure.

PickUp needle is equipped with stylet with pyramidal trocar tip that allows a quick and less invasive penetration into the cortical. The device is provided with an extraction wire with a measuring function of the specimen quantity present into the cannula, and off ers added safety for biopsy specimen extraction. The needle diameter with international color code is stamped on the packaging.
 
PickUp Needle offers more benefits than a Traditional Jamshidi Needle
Dot Avoids the complications caused by luxation movement which give pain to the patient
Dot Increases considerably the probability of positive outcome of the procedure
Dot Allows a simpler and safer extraction of the frustol from the needle because the sample is extracted together with the trap system.
 
The handle is provided with a sharpened Luer-lock to off er a more safety attachment to the syringe. Aspiration can be performed at any step of the procedure.

Optionally, Tap system can be supplied with double spoon (reference PJTD).
 
Code Gauge Length Color Code
PJT1306 13G 60 mm Cyan
PJT1310 13G 100 mm Cyan
PJT1110 11G 100 mm White
PJT1115 11G 150 mm White
PJT0810 8G 100 mm Green
 
 
 
 

Press-To

Bone Marrow Biopsy Needle without Luxation with Internal Trap Device

PressTo (PS) needle is a device for bone tissue biopsy provided with an internal trap system that allows the tissue extraction without luxation. The "T" ergonomic handle off ers optimal pressure and secure grip to facilitate the penetration step into the cortical.

The cannula of the needle is made with high quality stainless tempered steel and the centimeter markings on its surface, allow to easily determine the insertion depth into the bone tissue. The special "fish mouth" sharpening of the needle tip, improves the penetration capacity, establishing a perfect cylindrical cutting (till 3 cm) that maintains intact the sample architecture.

PressTo needle is equipped with a security system with rotation coupling which avoids the moving back risk of the stylet during the insertion step.
 
PressTo Needle offers more benefits than a Traditional Jamshidi Needle
Dot Avoids the complications caused by luxation movement which give pain to the patient
Dot Increases considerably the probability of positive outcome of the procedure
Dot Allows a simpler and safer extraction of the frustol from the needle because the sample is extracted together with the trap system.
 
PressTo needle is equipped with stylet with pyramidal trocar point that allows a quick and less invasive penetration into the cortical. The device is provided with a specimen pusher with a measuring function of the specimen quantity, present into the cannula, and offers added safety for biopsy specimen extraction. The needle gauge with international color code is stamped on the packaging.

The handle is provided with a luer Lock connector to offer an added safety attachment to the syringe. Aspiration can be performed also after the biopsy procedure.
 
Code Gauge Length Color Code
PS1306 13G 60 mm Cyan
PS1310 13G 100 mm Cyan
PS1110 11G 100 mm White
PS1115 11G 150 mm White
PS0810 8G 100 mm Green
 
 
 
 
Back View Product Brochure
 