Med Evolution
Download Our Catalogs
Mother & Child Products
Procedure Trays & Kits
Biopsy Needles
Feature Products

Soft Tissue Biopsy

EasyLock

Needle for Soft Tissues Biopsy by Aspiration as for "Menghini" modified

EasyLock (PC) needle, is provided with an atraumatic sharpened cannula made with AISI 304 steel and a "Menghini" tip. The disposable device is used for soft tissues biopsy such as kidney, lymph nodes, liver and thyroid. Removable cannula with centimeter markings for a simple insertion depth evaluation.

The sliding stopper allows to easily determine the depth to reach. The internal echogenic marker enhances the ultrasound visibility avoiding the cells spread during the biopsy procedure.
 
The device is provided with internal stylet with the following functions
Dot To facilitate the device penetration without skin incision
Dot To avoid the tissue penetration into the lumen of the cannula before reaching the target
Dot To gradually transmit the created vacuum from the syringe, on the needle tip (thanks to a special processing present on the surface of the stylet)
Dot To avoid the sample aspiration into the cylinder of the syringe, keeping the sample into the cannula and to facilitate the expulsion step
 
The needle is provided with a sharpened Luer-lock to off er an added safety attachment to the syringe without vacuum loss.

Otpionally NeedleVise®safety device can be added (PCR code)
 
Gauge Outer Diameter Code Length 70 mm Code Length 100 mm Code Length 120 mm Code Length 150 mm Code Length 200 mm
18 1.27 PC1807 PC1810 PC1812 PC1815 PC1820
19 1.10 PC1907 PC1910 PC1912 PC1915 PC1920
20 0.90 - PC2010 PC2012 PC2015 PC2020
21 0.80 - PC2110 PC2112 PC2115 PC2120
22 0.70 - PC2210 PC2212 PC2215 PC2220
 
 
 
 

EasyCut Coaxial

 
The needle is provided with a sharpened Luerlock to off er an added safety attachment to the syringe EasyCut Coaxial (PC0C) is a combination of an EasyCut needle and a coaxial introducer needle with size and length studied to be exactly coupled to each other. The introducer may be left in position inside the patient, allowing the execution of multiple procedures. without vacuum loss.
 
Gauge Diameter Code Length 70 mm Code Length 100 mm Code Length 150 mm Code Length 200 mm
16 - PC0C1607 PC0C1610 PC0C1615 PC0C1620
18 1.27 PC0C1807 PC0C1810 PC0C1815 PC0C1820
20 0.90   PC0C2010 PC0C2015 PC0C2020
 
 
 

HandCut

 

Manual tru-cut needle for soft tissues biopsy with guillotine system

HandCut (PM) needle is a disposable device for soft and fi brous tissues biopsy that need to be cut for their remotion.

The "Menghini" sharpening of the cannula, allows cutting and acquisition of the specimen. The stylet has a triple ultra-sharp tip to penetrate easily also into fi brous tissues and has a 20mm specimen notch for sample capturing.

Sliding stopper and centimeter markings on the cannula, to easily determine the insertion depth.
 
The device is equipped with
Dot Internal echogenic marker to enhance the ultrasound visibility avoiding cells spreading during the biopsy procedure
Dot Length limitator to take samples of 10mm in length
Dot Luer-lock that allows the connection to the syringe for Cytological aspiration
 
Gauge Outer Diameter Code Length 75 mm Code Length 100 mm Code Length 114 mm Code Length 150 mm
14 2.10 PM14075 PM1410 PM14114 PM1415
16 1.60 PM16075 PM1610 PM16114 PM1615
18 1.20 PM18075 PM1810 - PM1815
 
 
 
 

Semicut

Ultra-Light Semiautomatic Tru-Cut Needle for Soft Tissues Biopsy with Guillotine System with Non-Removable Cannula.

Semicut is a disposable device provided with removable cannula with enhanced echo-visibility made with AISI 304 steel with a "Menghini" tip that allows an atraumatic precise cutting of the tissue. A sliding stopper and centimeter markings on the cannula surface allow an easily determination of the depth of insertion.

The biopsy specimen, can be taken with two diff erent length: 10mm or 20mm. Semicut, after cannula loading, can be used with a single hand, leaving the other free to handle other devices such as ultrasound guide etc.
 
The stylet is equipped with
Dot Ultra-sharp triple tip to penetrate easily also into fi brous tissues
Dot A 20mm specimen notch for the sample capture
 
Optionally, Semicut, can be provide with a coaxial introducer needle, with pyramidal tip stylet. Needle size, with international colour code, stamped on the handle of the needle.

Semicut, is the lightest semiautomatic device on the market; this characteristic is very important because allows the User to leave the device safely inserted into the patient without support it.
 
Gauge Outer Diameter Code Length 70 mm Code Length 100 mm Code Length 150 mm Code Length 200 mm
14 2.10 PD01407 PD01410 PD01416 PD01420
16 1.60 PD01607 PD01610 PD01616 PD01620
18 1.20 PD01807 PD01810 PD01816 PD01820
20 0.90 PD02007 PD02010 PD02016 PD02020
 
 
 
 

Themy

 

Automatic Disposable Device for Soft Tissues Biopsy

Themy(R)(TY/TYS) is an automatic, disposable device equipped with a sequential advancement system of cannula and stylet. Themy is a lightweight device that off ers a spring loaded action that allows an accurate and easy penetration inside fi brous or calcifi ed lesions The device, is equipped with a AISI 304 stainless steel cannula with a "Menghini" sharpening that allows an atraumatic precise cutting of the tissue. The cannula is provided with centimeter markings to easy determine the depth of insertion for the safety of the patient.

Themy(R) is a very stable and ultralight automatic device. It can be provided in two versions with diff erent lenght of notch: 10mm (TYS) or 20 mm (TY). Needle size, with international colour code, is stamped on the hub and on the primary packaging. The stylet has a triple ultra-sharp tip to penetrate easily also into fi brous tissues. Possibility to take the sample with only one fi ring of the bottom.

Themy(R) is provided with two fi ring sequential trigger points, one in front and one at the back allowing to the doctor diff erent handling positions.

In each step of the procedure, the operator is able to know the charging status of cannula and stylet.
 
Two Firing Modes
Dot A mode: releases cannula and stylet in rapid sequence and captures tissue sample simultaneously.
Dot D mode: releases stylet and allows the user to wait the required time before to release the cannula by pushing the button till the point A.
 
Length Size 14G Size 16G Size 18G Size 20G
100mm TY1410 TY1610 TY1810 TY2010
120mm TY1412 TY1612 TY1812 TY2012
160mm TY1416 TY1616 TY1816 TY2016
200mm TY1420 TY1620 TY1820 TY2020
250mm - - TY1825  
300mm - - TY1830  
 
Themy(R) can be provided with a coaxial introducer needle that allow execution of multiple procedures (code TYC )
 
Code with Coaxial included Single Coaxial Needle Code Coaxial Cannula Length
TYC1410 PT13044 44mm
TYC1412 PT13064 64mm
TYC1416 PT13104 104mm
TYC1420 PT13144 144mm
TYC1610 PT15044 44mm
TYC1612 PT15064 64mm
TYC1616 PT15104 104mm
TYC1620 PT15144 144mm
TYC1810 PT17044 44mm
TYC1812 PT17064 64mm
TYC1816 PT17104 104mm
TYC1820 PT17144 144mm
TYC1825 PT17194 194mm
TYC1830 PT17244 244mm
TYC2010 PT19044 44mm
TYC2012 PT19064 64mm
TYC2016 PT19104 104mm
TYC2020 PT19144 144mm
 
 
 
 

Intro

 

Coaxial Introducer Needle

Intro (PT) is a introducer coaxial needle used as an insertion guid of cannulas, biopsy devices, catheters, breast localization wires or other devices in the human body.

Intro needle allows the execution of multiple procedures remaining into the patient, while the biopsy needle, going through the introducer needle, can be unloaded and reloaded.

Intro is equipped with stylet with trocar tip designed to have a tissue penetration less traumatic as possible.

Stylet hub coloured according to the international colour code. Universal connector Luer-lock and handle made with transparent plastic material to facilitate the fluid passage visibility.

Centimeter markings and sliding stopper to easily determinate the insertion depth with a maximum safety for the patient.
 
Code Outer Diameter Inside Diameter Length Gauge of the Needle to Introduce
PT1305 13G 2.17 50 mm 14G
PT13075 13G 2.17 75 mm 14G
PT13095 13G 2.17 95 mm 14G
PT13110 13G 2.17 110 mm 14G
PT13140 13G 2.17 140 mm 14G
PT1505 15G 1.70 50 mm 16G
PT15075 15G 1.70 75 mm 16G
PT15095 15G 1.70 95 mm 16G
PT15110 15G 1.70 110 mm 16G
PT15140 15G 1.70 140 mm 16G
PT1705 17G 1.32 50 mm 18G
PT17075 17G 1.32 75 mm 18G
PT17095 17G 1.32 95 mm 18G
PT17140 17G 1.32 140 mm 18G
 
 
 
 

Palium

 

Automatic reusable device for soft tissues biopsy

Palium is an automatic, reusable device equipped with a sequential advancement system of cannula and stylet.

Designed to get an high quality of the core specimen. Ultra-sharp tips and polished surfaces for a better entry and exit.

Powerful dual spring system for consistent and excellent core samples. Rapid-fi re action. Small size and lightweight. One hand activation to provide easy access to the tissue sample. Dual penetration depths for fl exibility and convenience (22mm or 15mm).

The samples can be taken with just one fi ring of the button. Can be easly armed with just one hand. May be sterilized with conventional methods.
 
Features a side entry for FastCut needle spacer
Dot Safety to avoid accidental fi ring.
Dot Trigger site on the rear.
Dot Security button.
 
Use exclusively with FastCutM, MDL's needle.

Sequential loading system that requires a slight activation force. Advancement lengths: 15 - 22mm.
 
 
 
 

FastCutM

Tru-cut needle for Soft Tissues Biopsy to use with Automatic Gun Type Magnum® Bard®

FastCutM is a tru-cut disposable biopsy needle studied for use with Palium and also suitable for use with Bard® Magnum® reusable gun.
 
The device, is equipped with
Dot Cannula made with AISI 304 steel
Dot "Menghini" sharpening that allows an atraumatic precise cutting of the tissue
 
Centimeter markings and sliding stopper on the cannula surface to easily determinate the insertion depth with the maximum safety for the patient.

The handle is provided with a Luer connection to allow the connection to the syringe for aspiration.

Needle size with international colour code stamped on the spacer and on the primary packaging.
 
The stylet has
Dot A triple ultra-sharp tip to penetrate easily also into fi brous tissues.
Dot A 20mm specimen notch for the sample capture.
 
Optional a coaxial cannula for multiple procedures performing is inserted into the packaging (MGC code).

Surface echogenic marker enhances the ultrasound visibility. The set includes a spacer with side entry to facilitate the positioning of the needle into the automatic system.

It is suitable for stereotactic procedure.
 
Code Needle without Coaxial Gauge X Length Coaxial Length OD/ID Coaxial Coaxial Code Code Item with Coaxial
MG1210 12G X 100 mm 44mm 2.50/2.17mm PT11044 MGC1210
MG1213 12G X 130 mm 74mm 2.50/2.17mm PT11074 MGC1213
MG1215 12G X 150 mm 94mm 2.50/2.17mm PT11094 MGC1215
MG1216 12G X 160 mm 104mm 2.50/2.17mm PT11104 MGC1216
MG1220 12G X 200 mm 144mm 2.50/2.17mm PT11144 MGC1220
MG1410 14G X 100 mm 48.5mm 2.42/2.17mm PT13048 MGC1410
MG1413 14G X 130 mm 78.5mm 2.42/2.17mm PT13078 MGC1413
MG1416 14G X 160 mm 108.5mm 2.42/2.17mm PT13108 MGC1416
MG1420 14G X 200 mm 148.5mm 2.42/2.17mm PT13148 MGC1420
MG1610 16G X 100 mm 48mm 1.93/1.70mm PT15048 MGC1610
MG1613 16G X 130 mm 78mm 1.93/1.70mm PT15078 MGC1613
MG1615 16G X 150 mm 98mm 1.93/1.70mm PT15098 MGC1615
MG1616 16G X 160 mm 108mm 1.93/1.70mm PT15108 MGC1616
MG1620 16G X 200 mm 148mm 1.93/1.70mm PT15148 MGC1620
MG1810 18G X 100 mm 48mm 1.52/1.32mm PT17048 MGC1810
MG1813 18G X 130 mm 78mm 1.52/1.32mm PT17078 MGC1813
MG1815 18G X 150 mm 98mm 1.52/1.32mm PT17098 MGC1815
MG1816 18G X 160 mm 108mm 1.52/1.32mm PT17108 MGC1816
MG1820 18G X 200 mm 148mm 1.52/1.32mm PT17148 MGC1820
MG1825 18G X 250 mm 198mm 1.52/1.32mm PT17198 MGC1825
MG1830 18G X 300 mm 248mm 1.52/1.32mm PT17248 MGC1830
MG2010 20G X 100 mm 48mm 1.13/0.95mm PT19048 MGC2010
MG2013 20G X 130 mm 78mm 1.13/0.95mm PT19078 MGC2013
MG2016 20G X 160 mm 108mm 1.13/0.95mm PT19108 MGC2016
MG2020 20G X 200 mm 148mm 1.13/0.95mm PT19148 MGC2020
 
 
 
 

FastCutP

Tru-Cut Needle for Soft Tissues Biopsy to use with Automatic Gun Type PRO_MAG 2.5TM

FastCutP (MGP) is a tru-cut disposable biopsy needle for Pro-Mag 2.5TM
 
The device, is equipped with
Dot Cannula made with AISI 304 steel
Dot "Menghini" sharpening that allows an atraumatic precise cutting of the tissue
 
Centimeter markings and sliding stopper on the cannula surface to easily determine the insertion depth with the maximum safety for the patient.

Needle size with international colour code stamped on the spacer and on the primary packaging.
 
The stylet has
Dot A triple ultra-sharp tip to penetrate easily also into fi brous tissues.
Dot A 20mm specimen notch for the sample capture.
 
Code without Coaxial Gauge X Length Coaxial Length OD/ID Coaxial Code Coaxial Code Item with Coaxial
MGP1410 14G X 100mm 44.5mm 2.42/2.17mm PT13044 MGPC1410
MGP1412 14G X 120mm 64.5mm 2.42/2.17mm PT13064 MGPC1412
MGP1416 14G X 160mm 104.5mm 2.42/2.17mm PT13104 MGPC1416
MGP1420 14G X 200mm 144.5mm 2.42/2.17mm PT13144 MGPC1420
MGP1610 16G X 100mm 44mm 1.93/1.70mm PT15044 MGPC1610
MGP1612 16G X 120mm 64mm 1.93/1.70mm PT15064 MGPC1612
MGP1616 16G X 160mm 104mm 1.93/1.70mm PT15104 MGPC1616
MGP1620 16G X 200mm 144mm 1.93/1.70mm PT15144 MGPC1620
MGP1810 18G X 100mm 44mm 1.52/1.32mm PT17044 MGPC1810
MGP1812 18G X 120mm 64mm 1.52/1.32mm PT17064 MGPC1812
MGP1816 18G X 160mm 104mm 1.52/1.32mm PT17104 MGPC1816
MGP1820 18G X 200mm 144mm 1.52/1.32mm PT17144 MGPC1820
MGP1825 18G X 250mm 194mm 1.52/1.32mm PT17194 MGPC1825
MGP1830 18G X 300mm 244mm 1.52/1.32mm PT17244 MGPC1830
MGP2010 20G X 100mm 44mm 1.13/0.95mm PT19044 MGPC2010
MGP2012 20G X 120mm 64mm 1.13/0.95mm PT19064 MGPC2012
MGP2016 20G X 160mm 104mm 1.13/0.95mm PT19104 MGPC2016
MGP2020 20G X 200mm 144mm 1.13/0.95mm PT19144 MGPC2020
 
 
 
 
 
Back View Product Brochure
 

© 2014 MedEvolution. All Rights Reserved.